Interior Door Transport, Storage, Installation, Operation and Care Instructions, Including Warranty Conditions

Document version: 2026_10_09, updated and published on 9 October 2026.

The current edition of this instruction is available on the SIA Brodoor website under Terms and Conditions.

Manufacturer: SIA Brodoor

Scope: All types of interior doors manufactured and distributed by SIA Brodoor, including wooden, veneered, painted, HPL-faced, glass and fire-resistant doors, for which the following supporting certificates are maintained:

  • ISO 9001:2015 standard certificate;
  • Factory production control certificate;
  • Fire-resistance conformity certificate;
  • Sound-insulation test reports;
  • Test reports on impact resistance of the door surface and door set, vertical load, repeated opening and closing, and static torsional strength.

Introduction and General Terms

This instruction is an official technical document setting out the rules for safe transport, storage, professional installation, daily operation, periodic care and warranty coverage of SIA Brodoor interior doors and their components.

WARNING! We recommend entrusting door-set assembly and installation in the opening to a professional installer. If you decide to carry out this work yourself, please read these instructions carefully. Failure to follow this instruction or the manufacturer's directions excludes the possibility of receiving warranty service and may cause irreversible damage to the product.

Download the original PDF in Latvian

www.brodoor.lv | [email protected]

1. Door Transport and Storage Requirements

Before doors are brought to the installation site, suitable conditions must be provided to protect the product from material deformation and aesthetic damage.

1.1. Basic Storage Requirements

  • Before installation, store doors in dry, enclosed and well-ventilated rooms, protected from precipitation, direct sunlight and mechanical damage.
  • Doors must be stored only in a horizontal position on a flat, smooth base or on special pallets that fully prevent the door leaf or frame from bending, twisting or becoming indented.
  • Place evenly sized wooden or foam spacers between stacked doors to allow air circulation.
  • Strictly protect door surfaces from prolonged exposure to moisture, as moisture may cause the wood to swell, the veneer to delaminate or the paint finish to be irreversibly damaged.
  • Do not leave doors in packaging, whether waterproof film or original packaging that fully protects them from the environment, for more than 10 days, as condensation may form and damage wooden surfaces.
  • When carrying out interior finishing work, such as painting or filling, fully cover the doors with protective film. The adhesive side of the film or adhesive tape must not touch painted or veneered door surfaces directly. Use only special painter's tape that leaves no adhesive residue.
  • During storage, observe the room microclimate requirements in section 3.1.

Storage-condition symbols: temperature range +10°C to +40°C; relative humidity 45-65%; protect from frost; avoid direct sunlight; do not keep doors in rain or damp conditions.

1.2. Transport Requirements

  • During transport, moderate fluctuations in humidity and temperature must be maintained inside the vehicle.
  • Transport doors only horizontally on pallets, securing them firmly against sliding or tipping and packing them in waterproof film or packaging that fully protects them from the environment.
  • Do not drag, push, roll or throw doors. Move them only by carrying them carefully.
  • Painted or lacquered surfaces must never come into contact with organic solvents or water.
  • Do not remove the door identification labels during transport.

2. Door Installation Instructions

Before starting installation, check the product quality and that the package is complete:

  • Door leaf;
  • Door-frame set, including vertical and horizontal parts;
  • Hinges, lock mechanism and strike plate;
  • Threshold, automatic drop-down threshold and door closer, if specified;
  • Casings and cover trims for double or one-and-a-half leaf doors;
  • Installation screws and plastic decorative caps;
  • The buyer must inspect the product's external appearance on receipt and before any installation or processing work is carried out.

2.1. Site and Work-Area Readiness Before Installation

Before the doors are delivered to the installation location and installation begins, check whether the actual site conditions allow the doors to be safely unloaded, stored and installed without risk of damage, deformation or loss of quality. The entire project does not have to be complete, but the installation area must meet these requirements:

  • The building is enclosed and the doors are protected from precipitation, direct water exposure and condensation.
  • Wet, dusty and other work that could damage the doors or interfere with correct installation is complete in the installation area. The rooms meet the temperature and relative-humidity conditions specified in this instruction.
  • The wall construction and opening are built, stable and suitable for the intended door fixing method. The opening dimensions, geometry and wall thickness comply with the approved door specification and installation solution.
  • The finished floor has been laid, or its final height has been recorded in writing. The base required for installing the threshold and frame is prepared.
  • There is safe access to the installation location and sufficient clear working space. Building materials, scaffolding, services or other obstacles do not obstruct access or installation.
  • If the doors must be stored at the site before installation, a suitable place has been prepared and protected from moisture, dust, mechanical damage and access by unauthorised persons.
  • There is a plan for protecting the installed doors from subsequent construction work, moisture, dust and mechanical damage until the project is complete.
  • If any requirement is not met, the installer records the specific non-conformity before starting work and informs the customer or the person responsible for the site.

2.2. Preparing the Wall Opening

  • Begin installing doors only after all wet construction work, including plastering walls, filling and concreting floors, has been fully completed and the rooms have dried completely. Do not install doors before this work is complete.
  • Check that the door opening dimensions match the door set. The opening sides must be level and vertical, and the corners must be square at 90 degrees.
  • The door opening must be 15-45 mm larger than the outside dimensions of the frame to provide sufficient space for installation foam or insulation material.
  • The threshold base and floor in the opening area must be level, horizontal and firm. In rooms with increased humidity, install the frame with a 1-2 mm clearance from the floor to prevent direct contact with the floor covering.

2.3. Assembling and Fixing the Frame

  • According to the door handing, left or right, join the vertical and horizontal frame parts with wood screws. It is recommended to screw the threshold on before placing the frame in the opening to ensure the frame is perfectly square and to prevent gaps.
  • Place the assembled frame in the door opening. Secure it in the opening using wedges or special frame sleeves.
  • Using long and short spirit levels, check that the frame uprights, horizontal parts and threshold are completely straight. The maximum permitted deviation from vertical is 1 mm per 1 metre.
  • Fix the hinge side of the frame to the wall using plugs and screws suitable for the wall type.
  • Measure the frame diagonals. They must be exactly equal. The gap between the frame and the door leaf to be installed must be even and parallel around the entire perimeter, usually 3-3.5 mm.

2.4. Hanging the Door Leaf and Filling Gaps

  • Place the door leaf on the hinges. Check that the strike-plate side is straight relative to the wall and that the leaf opens easily without rubbing.
  • Fill the open gaps between the frame and wall with insulation material, either stone wool with a density greater than 50 kg/m3 or special installation foam.
  • Use suitable fire-resistant foam when installing fire doors, for example Penosil Fire Rated Gunfoam B1 187.
  • Important: When using installation foam, temporary braces must be placed inside the frame to prevent the frame profile from bowing and deforming as the foam expands.
  • Attach the casings and insert the plastic decorative caps into the installation screw holes.

3. Door Operating Requirements

3.1. Room Microclimate

  • Doors are intended for use only in dry, warm, heated and ventilated indoor spaces.
  • Room air temperature must be between +10°C and +40°C, and relative air humidity must be 45-65%. Avoid sudden changes in temperature and humidity.
  • Do not install doors closer than 0.5 to 1 metre from heat sources such as radiators or heating boilers.
  • Protect doors from direct sunlight, as UV radiation accelerates ageing of lacquer and paint coatings and changes their colour.

3.2. Correct Use and Safety Warnings

  • Open and close doors only by pressing the door handle by hand. Do not press the handle with any other weight or object, your foot or a walking stick.
  • Safety in the door-leaf path: When using the door, keep hands and feet out of the closing path of the leaf, both on the hinge side and on the side of the door mechanism.
  • Open doors to an angle of 90 degrees. Do not allow them to strike a wall, furniture or a floor-mounted door stop with force. Place floor-mounted door stops at a distance of 1/3 of the door-leaf width from the lock side, or 2/3 from the hinge side.
  • Close doors smoothly, without slamming.

Handle diagram: Incorrect: lifting the handle upwards. Correct: press the handle down. Correct: turn the handle.

3.3. Strict Prohibitions

  • Do not hang from, lean on or swing on the door leaf, or climb on casings or jambs.
  • Do not expose doors to direct water, steam or aggressive liquids.
  • Do not attach objects, adhesive tape or labels to the door surface unless this has been agreed in advance.
  • Do not make unauthorised holes or millings in the door, saw it, or shorten or trim the door leaf.
  • Do not remove seals, fire-resistant strips, automatic drop-down thresholds or the manufacturer's identification labels. Do not place cardboard, plastic, rugs or other objects under automatic drop-down thresholds.
  • Do not unscrew or remove door installation screws without authorisation. If any screw or fixing point has been removed or loosened, do not use the door until all screws have been correctly refitted.
  • On fire doors fitted with a door closer, do not disable or dismantle the closer, or make any unapproved changes after the door is put into operation.

Prohibition-symbol captions: operate the door by hand; do not use your feet; do not use chemicals; do not drill, saw or nail; do not apply mechanical force.

4. Door Care

4.1. General and Daily Care

  • Regular cleaning: Regularly clean the doors, hardware, threshold, seals and hard-to-reach areas to remove dust and dirt.
  • Daily care: Use furniture-care products and a soft cotton cloth dampened with water. Always dry the surfaces after cleaning.
  • Glass care: Once a week, remove dust from door glass with a dry cloth or a product specifically intended for glass. Make sure the cleaning product does not get onto wooden door surfaces.
  • Removing installation foam: Do not clean installation-foam residue while it is fresh or use chemicals. Wait until it hardens, then remove it carefully by mechanical means without scratching the surface.

4.2. Surface Types and Specific Care

  • Painted surfaces: Paint reaches its final hardness and durability within 1 month. Treat painted surfaces with particular care during the first month. Use neutral cleaning products with pH 6-8.
  • HPL surfaces: These are relatively resistant to household damage. Wipe them with a damp cloth every 3 weeks. Stubborn stains may be cleaned with a mild soap solution or a minimal amount of alcohol or acetone, then rinsed thoroughly.
  • Veneered surfaces: Do not use abrasives or solvents. Avoid excess moisture. Clean stains with a mild furniture-care product and dry the surface immediately.

4.3. Products Strictly Prohibited for Cleaning

  • Abrasive cleaning products, pastes and powders;
  • Dishwashing and laundry detergents;
  • Organic solvents such as acetone, ethyl alcohol and similar products, except for a minimal amount on stubborn stains on certain HPL surfaces;
  • Floor-cleaning products and cosmetics removers;
  • Concentrates containing acids or alkalis.

During and after the warranty period, the end customer is responsible for caring for the doors and finishes. If the end customer does not wish to perform this care or does not have the appropriate competence, these services may be ordered for a separate fee.

5. Hardware Maintenance and Adjustment

  • Preventive inspection: Once every 6 months, or more often in cases of intensive use or when required by the relevant hardware manufacturer's instructions, inspect the fixing screws of locks, hinges and handles and tighten them if necessary.
  • Lubrication: If needed, for example if door hinges or locks squeak, use suitable lubricants on the hinges and locks. Do not allow lubricant to contact the product's finished, lacquered or painted surfaces.
  • Lock latch and strike plate: Keep the lock latch and strike plate clean. The door must close freely without pressing the handle. If the door closes with resistance, adjust the strike plate or hinges.
  • Handle construction: Handles must fit firmly against the door surface. Periodically check and tighten the through-bolts and the fixing screws on the spindle.
  • Automatic thresholds and closers: The automatic threshold must fully seal the gap beneath the door leaf, but must not press against the floor with excessive force. The closer must ensure that the door closes fully but gently.

During and after the warranty period, the end customer is responsible for hardware maintenance and adjustment. If the end customer does not wish to perform this maintenance or does not have the appropriate competence, these services may be ordered for a separate fee.

6. Manufacturer's Warranty and Claims

6.1. Warranty Coverage and Term

SIA Brodoor provides a 2-year manufacturer's warranty for the door leaves, frames and finishes it manufactures. Hardware and glazing are covered by the relevant manufacturers' warranty terms.

6.2. Compliance Criteria

The following compliance criteria are specified in SIA Brodoor's technical requirements for interior door manufacturing, LV UTN 45403006398 - 2 - 2021.

Door leaves

  • Width: +/- 1.0 mm (Class 3, LVS EN 1529);
  • Height: +/- 1.0 mm (Class 3, LVS EN 1529);
  • Thickness: +/- 0.5 mm (Class 3, LVS EN 1529);
  • Squareness: 1.0 mm (Class 3, LVS EN 1529) / diagonal: 4 mm (Class 3, LVS EN 1530);
  • General flatness: height up to 4 mm (Class 3, LVS EN 1530), width up to 2 mm (Class 3, LVS EN 1530);
  • Primed: unfilled, unsanded, with a primer coating (SIA Brodoor standard);
  • Painted: filled, sanded, white-painted, semi-matt (SIA Brodoor standard);
  • Laminated: faced with 0.8 mm HPL boards with a 1-2 mm ABS edge (SIA Brodoor standard);
  • Veneered: faced with knife-cut veneer, sanded and lacquered (SIA Brodoor standard).

Frames

  • Width: +/- 0.5 mm (SIA Brodoor standard);
  • Thickness: +/- 0.5 mm (SIA Brodoor standard);
  • Length: +/- 2 mm (SIA Brodoor standard);
  • Bowing across the width: 1 mm/m (SIA Brodoor standard);
  • Primed, painted, laminated and veneered finishes: according to SIA Brodoor standards.

Sets

  • Gap between the door leaf and frame: 1-3 mm (SIA Brodoor standard).

6.3. When the Warranty Term Starts

The warranty term and its start date are determined according to the buyer's status and the method of door delivery or installation:

  • Private individual, direct buyer: The warranty starts on the date of sale shown on the proof of purchase, such as a receipt or delivery note.
  • Retailers and resellers: The end customer's warranty starts when the end customer buys the doors. The store receipt or delivery note for the end buyer must be provided. Additional condition: The maximum storage period in the retailer's warehouse before resale is 12 months from the date the doors are issued by SIA Brodoor. If the doors are not sold within this period, the warranty may apply only after a prior technical inspection by the manufacturer.
  • Construction companies: The warranty starts on the date of sale shown on the proof of purchase, such as a receipt or delivery note.
  • If doors are delivered and installed by trained and authorised installation specialists of SIA Brodoor, the start date, terms and duration of the warranty for the doors and installation work are determined by the specific delivery and installation contract, subject to applicable mandatory legal requirements.

6.4. Warranty Exclusions

WARNING! The warranty does not cover damage or cases caused by:

6.4.1. Transport, Storage, Package Contents and Installation

  • Claims concerning the completeness or external quality of the product, including visible defects and scratches, are not accepted after any installation or processing work has begun. The product's appearance and completeness must be checked on receipt.
  • Significant damage caused by improper transport, loading or unloading, or storage, including prolonged exposure to moisture, storage in unheated or undried rooms before installation, signs of falling, scratches and similar damage.
  • Failure to follow installation rules or methods, or use of unsuitable materials.
  • Use of adhesive or other protective tape that damages the product surface. The installation team or buyer is responsible for using such tape.
  • Installation of doors in an unsuitable place or environment, for example using them as exterior doors or in rooms with an unsuitable microclimate. See section 3.1.

6.4.2. Incorrect Operation and Care

  • Mechanical impacts and incorrect operation, for example swinging the door by the handle while lifting it upwards or slamming the door against a wall.
  • Use of unsuitable chemicals, abrasives or solvents, or inadequate or incorrect product care.
  • Unauthorised actions by third parties, dismantling of the doors, or unauthorised repair or rebuilding attempts.
  • Damage caused by other household factors.

6.4.3. Natural Properties of Wood and Wear

  • Differences in grain pattern, colour range, shades and construction details resulting from the natural properties of wood and the characteristics of wood-effect lacquers. The manufacturer cannot guarantee identical appearance or grain arrangement.
  • Minor changes caused by temperature and humidity, appearing as natural warping or twisting of wood. This is not a manufacturing defect unless the door leaf, while in the frame, bows more than 4 mm from a straight edge.
  • Natural wear, including fading of paint due to direct sunlight and natural changes in wood tone or texture over time.
  • The warranty does not apply to moving hardware components, including handles, locks, closers and automatic thresholds. The relevant manufacturers' warranty terms apply to those components.

6.4.4. External Conditions

  • Damage caused by force majeure or natural disasters, such as floods, storms or fire.

6.5. Submitting a Warranty Claim

To submit a warranty claim for a defect, the buyer must provide a written application stating:

  • Proof of purchase and installation, such as a delivery note, receipt, installation record or site handover report;
  • The exact site address and contact information;
  • A detailed description of the problem and photographs or video clearly showing the defect;
  • Until the manufacturer's representative arrives or a decision is made, the doors must be kept in the same condition in which the defect was discovered.

www.brodoor.lv | [email protected]